Guide
Beaded curtains for windows
Backlit all day: why body-coloured glass belongs at a window, how length is measured from the sill, and what fades.
Open the reference
Guide · Install
This decision is made before the panel is ordered, because it changes the width. Make it afterwards and you have the wrong piece.
A beaded window panel: thirty strands of frosted sea-glass and seed beads on a turned dowel, falling to a scalloped arch hem ended with drop beads.
Hang inside the reveal for a neat, built-in look and a panel that cannot foul a curtain track, measuring the reveal's narrowest point and deducting a clearance. Hang across the face when the window has a projecting handle, a shallow reveal or an awkward shape, and order wider than the opening so the edges are covered.
Choosing a plane before ordering a width, then fixing into whatever is actually behind that plane.
Those are two decisions and the second one is a building question rather than a beadwork question. A reveal is usually timber-lined and easy. A wall face above a window may be plasterboard, masonry, or plasterboard on battens over masonry, and each wants a different anchor.
The reveal measured at three heights — head, middle and sill — because reveals are rarely parallel. Measuring an opening properly is the whole of this step; work from the narrowest.
Then a tape, a pencil, a level, a drill, and anchors chosen for the substrate. For a timber-lined reveal you need no anchors at all, which is the main practical argument for the reveal position.
Also: the window's operation. An inward-opening casement, a tilt-and-turn, or a projecting handle will decide this for you.
For a reveal fixing: measure the narrowest width, deduct a clearance at each side, and order to that. Mark two fixing points on the head of the reveal, set in from each end by about a tenth of the panel's width. Check level. Pilot, fix, hang by the dowel.
For a face fixing: measure the opening and add an overlap at each side so there is no light-edged gap. Mark the fixing points above the opening, high enough that the panel's hem lands where you want it. Establish what is behind the plaster, choose the anchor, and fix. Hang by the dowel.
Then settle it: run your hands down the panel in sections to separate crossed strands, and give it a day.
The spare beads, the original stopper beads, and the offcut of the batten if you used one. Also worth writing on the back of the architrave in pencil: the panel width and the date, which is the information you will want when you replace it.
Look along the hem. A level dowel gives a level hem, and a hem that is high at one end means a fixing has moved or was never level.
At a window there is a second check: sit where people sit and look at the edges. On a reveal fixing you will see two vertical lines of light at the sides. That is expected and it is the price of the built-in look; if it reads as a mistake rather than as a detail, the panel should have gone across the face.
Window-scale formats are a real and recurring part of what we make rather than cut-down door panels.
Window panels run on thirty hand-strung strands on a single wooden dowel, and the panel headers reference sets out the alternatives. A valance at roughly 120 × 30 to 40 cm dresses the top of an opening and holds about 900 to 2,000 beads on our 2027 design-render basis. A frosted sea-glass valance we built at 30 × 24 in used irregular glass beads of about four to five millimetres strung with seed beads, thirty strands, with a scalloped arch hem running from a 24-inch longest drop to a 10-inch shortest.
Café formats at 24 × 30 in run on a 100% cotton header band with a three-inch rod pocket, which changes the fixing entirely: a rod pocket header wants a rod, and a rod wants brackets or a reveal it can span.
At a window, a glass panel is less of a problem than people expect, because window formats are short. A valance in glass weighs a fraction of a full-length door panel.
The fixing still has to be right. In a timber-lined reveal, two screws and nothing else. Across the face, fixing into plasterboard needs a proper cavity anchor — adhesive hooks will not hold glass beadwork and should not be considered. Into masonry, a plug, or better, a timber batten plugged into the masonry with the panel hung off the batten.
Hanging does not affect the panel. The cord is only at risk if the panel is lifted by its strands, which happens more at windows than anywhere else because the installer is reaching across a sill, a radiator or a worktop and grabs what is in range.
Hold the dowel at both ends. If you cannot reach both ends, get a second pair of hands rather than taking the weight on the strands.
Glass: heavier per bead, hangs straighter, and at window scale entirely manageable. Acrylic: light, sways more in a draught, and a window is the draughtiest position in a room — specify a weighted end bead. Wood and bamboo: light and quiet, but keep them out of a reveal that condenses, because wood takes up moisture and swells around its drill hole. The bead materials reference divides the families.
Faux capiz disc columns: light and striking with light behind them, and the position where they look best. Handle them carefully against a reveal lining, because a laser-cut edge chips.
Ordering before deciding. A panel bought at the opening width will be too wide for the reveal and too narrow for the face, and it is not adjustable in width without removing strands.
Second: measuring the reveal at one height. An older house will have a reveal 2 cm narrower at the sill than at the head, and a panel made to the head dimension will foul the sides.
Third: the handle. A tilt-and-turn or an inward casement handle occupies the reveal plane, and no amount of clearance makes a panel work there. Go across the face.
Hang it from a single central hook. Tie the dowel to a radiator pipe or a curtain track. Trim strands to clear a handle, which leaves a notch in the hem that reads as damage. Lift it by the strands.
And never fix a glass panel to plasterboard with an adhesive hook, however much the packaging claims.
Half an hour in a timber-lined reveal. An hour across the face, because establishing and fixing into the substrate is the real work and it is worth doing slowly.
Then a day of settling before judging the result, which at a window is the step most often skipped because the panel is in constant view.
Extractable data
| Inside the reveal | Across the face | |
|---|---|---|
| Width to order | Reveal width at its narrowest, less clearance | Opening width plus an overlap each side |
| Look | Built-in, architectural | Applied, softer, makes the window look larger |
| Light at the edges | A visible gap each side | Covered |
| Fixing goes into | The reveal lining or head | The wall above the opening |
| Fixing difficulty | Easy if the reveal is timber-lined | Depends on the substrate: plasterboard needs an anchor |
| Handle clearance | Only if the handle is clear of the panel plane | Always clear |
| Works with a blind behind | No — the blind takes the reveal | Yes, this is the layered arrangement |
| Formats that suit | Window panel, 30 strands on a dowel | Valance about 120 × 30–40 cm; café 24 × 30 in |
| Strand pitch | About 2.25 cm at 90 cm wide | About 2 cm at 120 cm wide |
Good to know
A retail display almost always wants the face position, because it reads from further away and because a shop window reveal is usually occupied by something else. Fix a timber batten across the face into structure and hang from that, so the panel can be moved for each window change without new holes.
Re-string it with the panel flat on a table before hanging, in bead-map order, from your spare beads if the order specified them. Finish the end with a crimp or the original stopper bead. A window installation is usually done at arm's length over furniture, which is the worst place to be fixing a strand.
Half an hour, and most of it is measuring. For a reveal fixing, measure the width at the top, the middle and the bottom and work from the narrowest — a reveal that is 2 cm narrower at the sill than at the head is entirely normal in an older house and is the usual cause of a panel that will not fit.
The panel is unaffected by hanging. A reveal fixing leaves two small holes in the lining, which fill and touch in invisibly. A face fixing leaves holes in the wall, which need filling properly. If no holes at all are acceptable, use a tension rod inside the reveal on a light panel.
A tape, a pencil, a level, a drill and the right anchors for the substrate. A reveal fixing into timber needs no anchors at all. A face fixing into plasterboard needs a proper cavity anchor, and into masonry a plug — and that choice is the single most important part of the job.
Not if you lift the panel by its dowel. Window installations are where strands get pulled most often, because the installer is reaching over a sill or a radiator and takes hold of whatever is nearest. Hold the dowel at both ends and let the strands hang.
A glass panel at window height is shorter and therefore lighter than a door panel, so the fixing is easier than it sounds. What changes is the face-fixing substrate: a glass panel on adhesive hooks in plasterboard will come off the wall. Into masonry with a plug, or into a timber batten, it is straightforward.
Keep exploring
Guide
Backlit all day: why body-coloured glass belongs at a window, how length is measured from the sill, and what fades.
Open the referenceGuides
One guide per question that arrives often enough to be worth answering properly.
Specs and sizesGuide
Which part of a frame is solid, where to position the fixing relative to the door swing, and the screws that hold.
Specs and sizesGuide
Three causes in order of likelihood: a header that is not level, a dowel that has rolled, and strands that have not settled yet.
Specs and sizesGuide
What settling is, how long it takes, how to help it along, and why nothing should be cut until it is finished.
See the detail
Start a conversation
Send a reference, a colour chip or a sketch. Minimums are set per design and confirmed per quote; sampling is quoted separately and usually runs 16 to 20 days from an agreed brief.