Guide
Fixing a damaged panel
Identify what failed, re-string that strand, re-knot it at the header, and match the bead from the spares specified with the order.
View the rangeSpecification · Maintenance
A bead panel is repairable if somebody ordered the parts. Ordered later, in a different dye lot, those parts are visible from across the room.
Hold spare beads in every colour in the panel, pre-made replacement strands cut to the drops the design uses, the cord specification, and the colour-count sheet. All of it is ordered with the panels so it comes from the same production run and the same dye lot. A knotted cord strand can be re-strung by hand.
Whether the panel is a repairable asset or a replaceable one. That is settled by a line in the specification, and it is settled at order stage because spares have to come from the same production run.

The second decision is who fits them, which depends on the construction more than on the person.
| Item | What to specify | Why |
|---|---|---|
| Pre-made replacement strands | A quantity per drop length the design uses | Already the right length and sequence; fitted without re-stringing |
| Spare beads, by colour | Every colour in the panel, from the same dye lot | A later dye lot of a surface-dyed bead will not match |
| Spare end beads | The most exposed and most replaced bead | They are where a panel physically wears |
| Spare spacer or locking beads | Where the design uses them | A blossom or accent slides without its spacer |
| Cord specification | Type and gauge, recorded | A field repair needs the same cord, not a similar one |
| Colour-count sheet | Issued with the spares | Without it a replacement strand cannot be built correctly |
| Cleaning trial strand | One strand reserved | So cleaning products are tested off the panel |
| Spares quantity | Agreed per installation | No percentage is published |
| Storage condition | Dry, labelled, with the sealed sample | Spares in a damp store are not spares |
The spares package as a priced specification item: pre-made replacement strands by drop length, spare beads by colour, spare end beads and spacers, the cord specification, the colour-count sheet and a cleaning trial strand.
Quantities are agreed per installation. No spares percentage is published, because the right quantity depends on the setting rather than on the panel.
Decide how many drop lengths the design actually uses. A straight hem uses one. A shaped hem uses as many as there are strands, which means the spares are specified as a quantity per length band rather than as a single figure.
Then set the quantity from the setting: a doorway in daily use consumes end beads, a wall panel consumes almost nothing. Then order everything with the panels so it comes from the same run and the same dye lot.
Maintenance is what consumes spares, so the quantity should follow the maintenance reality. A panel walked through a hundred times a day will lose end beads and eventually a strand. One on a wall at high level will lose very little and may lose beads only when it is cleaned.
A flat percentage across a package ignores that and either over-supplies the wall panels or under-supplies the doorways.
Spares do not solve a dye-lot problem retrospectively. Surface-dyed bead colour is a batch property, so a replacement strand made from a later lot can be correct against the colour reference and visibly different from the panel it is going into.
The only remedies are to order spares with the panels or to hold the dye lot for the programme. There is no third answer, and shelf life is a storage question rather than a published figure: keep spares dark, dry and labelled with the dye lot.
That a hand-strung panel on knotted cord is genuinely repairable. A strand can be re-strung to the colour-count sheet and re-knotted, which is a workshop operation and in simple cases a site one, and spare beads ordered with the panel are what make it possible.
Crimped coated wire is different: it needs a crimp tool and cannot be re-knotted by hand, which moves the repair from a facilities task to a workshop return.
The spares inventory, the storage location, the cord specification and the colour-count sheet. All four, because any one of them missing turns the spares into loose stock.
Storage matters more than it sounds: spares in a damp store are not spares, particularly where the panel uses wood or bamboo beads.
Glass panels need more spares than acrylic ones, because glass chips when knocked hard and acrylic does not shatter. Faux-capiz discs need spares because the surface dulls and a replaced disc restores a column.
Hand-formed beads are the hard case. Lampwork icon beads vary from piece to piece by nature, so a spare is a close relative rather than a duplicate, and the spares quantity should be generous because selecting the closest match consumes stock.
None on colour, which is why the ordering discipline matters. On length, the pre-made strands should match the drops exactly, which is achievable because they come off the same counted sheet as the panel.
For a linked-disc construction the lengths step by disc diameter, so the spares inventory is a set of discrete lengths rather than a range.
It is not, and that is the recurring failure. A spares package sits in nobody's natural scope: not the contractor's, not the installer's, not the facilities team's.
Unless the specifier writes it into the specification as a priced item with quantities, it does not get bought. That single sentence is the most valuable thing on this page.
The specification carries the spares package definition and the storage requirement. The schedule carries the quantities, because they vary per location with the setting.
The operation and maintenance manual carries the inventory and the location, and the colour-count sheet should be filed with both.
Spares ordered after handover, in a different dye lot, at the back of a production queue, for a handful of strands. The panel is repaired and the repair is visible.
The other failure is spares that exist and cannot be used, because nobody kept the colour-count sheet and so nobody knows which strand position a given sequence belongs to.
One pre-made replacement strand, supplied with the sample, fitted to the sample panel by the installer. It takes ten minutes and it proves that the repair is practical with the header design chosen.
A header that makes a strand replacement awkward is worth knowing about before thirty of them are installed.
Good to know
Nobody coordinates a spares package, which is why it gets missed. It is not the contractor's scope, not the installer's and not facilities, and unless the specifier puts it in the specification as a priced item it does not get bought.
The spares inventory, where the spares are stored, the cord specification and the colour-count sheet. A spares box in a store with no inventory and no sheet is a box of beads, not a spares package.
The spares package as a specification item, with quantities per drop length. It belongs in the specification rather than on the drawing, but it has to be somewhere priced, because a spares line nobody priced is a spares line nobody supplied.
On colour, none, which is the point: spares from the same dye lot match and spares from a later lot may not. That is why the spares are ordered with the panels rather than later, and why the dye-lot policy covers them.
The replacement strand itself, fitted. Ask for one pre-made strand with the sample and have the installer fit it to the sample panel. It demonstrates that the repair is actually practical with the header design chosen.
Maintenance consumes spares, which is their purpose. A panel in a busy doorway will lose end beads and occasionally a whole strand; a panel on a wall will lose almost nothing. The quantity should follow the setting rather than a flat percentage.
Keep exploring
Guide
Identify what failed, re-string that strand, re-knot it at the header, and match the bead from the spares specified with the order.
View the rangeSpecification
The dimensions, strand values, fixings and performance limits a drawing and schedule have to carry.
View the rangeSpecification
A cleaning interval by setting, the method per material, who can reach the panel, and the spares held on site.
Compare the optionsSpecification
Tracks, joists, suspended rails and the services coordination a drawing has to show.
How it is madeSpecification
Metamerism between daylight, tungsten and LED, and how to sign bead colour off under the real light source.
Specs and sizes
Start a conversation
Send a reference, a colour chip or a sketch. Minimums are set per design and confirmed per quote; sampling is quoted separately and usually runs 16 to 20 days from an agreed brief.