Specification
Beadwork in a hotel lobby
Large-format panels, fire performance, the maintenance plan and the approvals a lobby specification has to clear before it gets built.
Specs and sizes
Application · Hospitality
A venue that never closes has no maintenance window. Everything about the build — module size, fixing, cleaning method, spares — follows from the fact that work has to happen around guests, or not at all.
A dense beaded panel of faceted crystal glass in jet black, smoke grey and antique gold, every facet catching a small crisp highlight.
A venue that operates around the clock compresses the maintenance window to a few overnight hours, and that changes the whole build: modules sized to be lifted down quickly, cleaning that needs no wet work, spares strung with the run, and a fire file that has to be satisfied before installation. No flammability rating is currently held for our bead panels.

Make a large interior surface memorable, in a building that is busy at four in the morning. Entertainment venues buy texture at scale because the architecture is often simple and the decoration carries the identity. Beadwork does that well: it moves, it catches light, and it reads from across a floor.
What the brief rarely says out loud is that the venue has no closing time. Everything practical follows from that single operating fact, and it is worth confirming before the first sketch.
A maintenance plan that works in hours. If the only clean possible is a dry dust from a lift, the design has to be one that stays acceptable under dry dusting alone.
Modules that come down. Two people, one shift, no scaffold tower. That determines module size far more than the grid does.
Dust tolerance. Conditioned air moves a lot of particulate; some venues add haze. Both land on horizontal bead faces.
A fire file answer. Large venues keep a fire strategy and a fire officer, and a hanging decorative surface is exactly what both exist to scrutinise.
Large beaded wall panels. Our reference project in hospitality is the beaded décor walls at a US casino resort. At venue scale we specify a wall as repeating modules, because a module is what makes it buildable, cleanable and repairable, and that is what we propose again.
Free-hanging drops are the alternative and the weaker one in this setting: they sway in conditioned air, they are harder to clean, and they are harder to protect from a crowd. A wall-mounted field avoids all three.
Material: body-coloured pressed glass, with specialty glass annealed for strength where a feature bead is wanted and the colours confirmed together, since glass strength is colour-dependent and some colours pair badly where beads knock.
We make the header rail each module hangs from. Above it, everything is the project's — engineered support, fixings, bracing, access equipment, installation labour.
The panel is weighed on the approved sample and the fixing is sized to that weight. Arithmetic over bead counts is not a substitute for it. What we supply is the measured finished weight of the approved sample, per module.
Specify the release mechanism explicitly. A module that needs a tool and two sets of hands in daylight is not a module that comes down at 4 a.m.
Three layers, and in a venue the top one dominates. The house fire file — a large venue's own fire strategy, often with an in-house fire officer who signs hanging décor individually. Code — NFPA 701 for hanging decorative material in the US, with UK, EU and Australian equivalents, all wanting a test report. Brand or operator standard — frequently stricter than code.
Where the house fire file governs, the build is tested for that project. It has to be the specified build — bead material, cord, header and mount all change the result, so a report against a different build is worthless — and the testing is quoted and scheduled alongside production. Interior-finish classification, egress sign-off and structural or seismic certification are arranged the same way, against the specified build. Our standing certifications are Sedex SMETA, FSC for wood, C-TPAT and Omega social compliance.

In service: dry only. A soft brush down each strand, header to hem, from whatever access the housekeeping team already has.
Off-panel, overnight: damp spot-cleaning of the beads at floor level, cloth wrung nearly dry, dried in the same pass. The cord never gets wet, in any setting, which is why damp work belongs off the wall rather than up a ladder.
Dust, on upward-facing surfaces. That is the whole reason to avoid flat discs at height in a venue and to favour round or faceted beads that shed.
Then colour consistency across a long run, which is a production control rather than a service issue — one approved sample, dye lots held to it, first-article and lot inspection. Then slow cord slackening over years, visible as a hem that no longer reads level, and fixable by lowering a module and re-tensioning rather than by replacing a wall.
Sampling is 16 to 20 days from an agreed brief, photographs approved before the sample ships. Production is 40 to 60 days after sample approval. For a venue, add two items at the front: a glass trial where a specialty bead is involved, because annealing and colour compatibility are settled at the furnace rather than on the drawing; and the flammability test schedule where the fire file demands a report. Landed duty paid delivery to a named US location is available as a single delivered price. Formal quotes follow within 48 hours of a specification, after a discovery call on anything multi-module.
Module size, count and joint detail. Overall field dimensions. Strand count or pitch per module. Bead material, shape, size and hole diameter per bead. Colour as Pantone references or physical chips. Header rail type and length per module. Hem shape with longest and shortest drop.
Then the venue-specific clauses most drawings miss: the release and rehang method, the overnight maintenance procedure, the spares allowance strung with the run, the access provision, and a fire-performance clause naming the test, the build, the lab and who pays. A drawing that says "fire rated" with nothing behind it will be returned.
The usual cost levers apply, bead size and material first. At venue scale a sixth lever appears and it is the biggest one — repetition. A field built from one repeating module costs materially less than the same area built as bespoke panels, and it is also the only version that can be serviced overnight.
Extractable data
| Item | What a 24-hour venue needs | Note |
|---|---|---|
| Format | Large beaded wall panels as repeating modules | How we specify a wall at venue scale |
| Module size | Liftable and rehangable by two people in one shift | Set by the overnight window, not the grid |
| Reference format | Wall-hanging and portal dual format, 90 × 67 cm | Developed 2026; a module starting point |
| Bead material | Body-coloured pressed glass; annealed specialty glass | Glass strength is colour-dependent |
| Surfaces to avoid | Flat upward-facing discs at height | They collect what the air handling carries |
| Cleaning | Dry only, in service; damp work off-panel | Guidance for the material, not a tested cycle |
| Spares | Strung with the production run | Overnight repair needs matched beads on site |
| Top fixing | Header rail per module; structure by others | We make the rail, not the support |
| Flammability | Tested on the specified build and quoted with the project | The house fire file governs |
| Acoustic performance | No data held | Beadwork is not an acoustic product |
| Inspection | First-article and lot AQL inspection | Our own Greater Noida quality house |
| Sampling | 16–20 days from an agreed brief | Photographs approved before the sample ships |
| Production | 40–60 days after sample approval | Published lead time for beaded décor |
Good to know
Dry only, while the venue is open: a soft brush drawn down each strand from header to hem. Anything damp happens with the module off the wall, at floor level, in the overnight window. That is the practical reason to design the assembly as liftable modules rather than one fixed surface — a panel that cannot come down can only ever be dusted from a lift.
Sampling is 16 to 20 days from an agreed brief, with photographs approved before the sample ships, and production is 40 to 60 days after sample approval. A venue programme should add a specialty-glass trial where one is needed and, where the house fire file requires a report, the lab schedule for flammability testing, which is quoted separately.
Dust on upward-facing bead surfaces, driven by conditioned air and, in some venues, by haze from the floor. It is a cleaning-access problem rather than a material one, which is why the module design matters more than the bead choice. After dust, colour consistency across a long run, and then slow cord slackening that shows as a hem no longer reading level.
Yes: the beaded décor walls at a US casino resort — large beaded wall panels. It is our reference project in this category, and the module construction is the part worth taking from it, because it is what makes a wall at venue scale buildable, shippable and maintainable one panel at a time.
Large beaded wall panels. At that scale we specify a wall as repeating modules, because a module is what makes it buildable, cleanable and repairable. Long free-hanging drops are possible but they move in conditioned air and they are hard to service, so a wall-mounted modular field is the safer specification in a venue with no closing time.
We make the header rail each module hangs from. The support structure, fixings, bracing and access equipment are designed and supplied by the project, and the panel is weighed on the approved sample and the fixing is sized to that weight. We supply the measured finished weight of the approved sample per module, which is the figure an engineer can size a fixing against. In a venue, also specify how a module is released and rehung in the dark by two people.
The house fire file governs, usually sitting on top of NFPA 701 in the US or the local equivalent elsewhere, and a large venue will often have its own stricter in-house standard plus an on-site fire officer. Where that file governs, the build is tested for that project and the report is issued against it, quoted with the work. Interior-finish classification, egress sign-off and structural certification are arranged the same way, against the specified build.
Keep exploring
Specification
Large-format panels, fire performance, the maintenance plan and the approvals a lobby specification has to clear before it gets built.
Specs and sizesPillar
Twenty settings, from a closet front to a hotel lobby, each with the format that suits it, the fixing it needs and the standard that applies.
Specs and sizesSpecification
Service traffic, kitchen-pass screening, cleaning between covers and the fire paperwork a restaurant or bar fit-out will ask for.
Specs and sizesSpecification
Salt air, humidity, strong daylight and open sides — and the coastal material palette that survives all four.
See the detailSpecification
Panel size, rigging, strand order on reassembly and a realistic set-up time for beadwork that travels to every show.
See the detail
Start a conversation
Send a reference, a colour chip or a sketch. Minimums are set per design and confirmed per quote; sampling is quoted separately and usually runs 16 to 20 days from an agreed brief.